TROUBLESHOOTING
1-181August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Kaaaw sk
ERROR CODE P2000 Turn OFF motor power.
An attempt is made to execute an operation or command which is not permitted with
motor power ON.
Example: ZZERO command.
Turn motor power OFF and re-execute operation or command.
_____________________________________________________________________
ERROR CODE P2001 Turn HOLD/RUN sw. to HOLD.
Occurs when an attempt to execute DO, STEP, MSTEP, CONTINUE, or EXECUTE
command is made with the RUN/HOLD switch in the RUN position. Only applies if the
CHECK.HOLD system switch is ON (AUX 0502).
Turn the RUN/HOLD switch to HOLD position.
_____________________________________________________________________
ERROR CODE P2002 There is no external axis.
External axis cooperative motion command is executed and external axis equipment is
not installed.
Enable option or contact customer service to install external axis option.
_____________________________________________________________________
ERROR CODE P2003 Illegal positioner type.
An out of range value is used to specify the type of positioner for an external axis.
Specify the positioner type with a value that is in range.
_____________________________________________________________________
ERROR CODE P2004 Cannot change, user data already exist.
An attempt is made to change system data (number of axes, etc.) without deleting
existing user data.
Save user data to PC card or floppy disk and delete user data from system memory.
Change system data and reload user data from PC card or floppy disk.
_____________________________________________________________________