TROUBLESHOOTING
1-23August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Kaaaw sk
! WARNING
ERROR CODE D1008 P-N low voltage [XX].
The voltage between P-N supplied to the power block is 60 VDC or less at servo on.
Because motor power is not supplied, when low voltage
occurs, the arm will fall until the error is detected. As a
result, other errors may be generated (abnormal speed,
deviation error, etc.).
1KB board 1KP board
P-N power low
voltage error
MC unit
(1KQ/1NQ board)
Primary power
Power block
Gate Array
Servo
CPU
Interface
CPU
P-N power
voltage
monitoring
circuit
Main
disconnect
EPLD
K3 STATUS
Motor power
Main causes include:
1. Motor power circuit connector detached or loose.
2. Three phase (U, V, W) control power circuit breaker set to OFF.
3. Defective 1KB/1KP/1KQ/1NQ boards.
4. Defective power block.
5. Defective MC unit or harness.

Ensure the motor power circuit connector is properly attached.

Ensure control power circuit breaker is set to ON.

Replace the 1KB/1KP/1KQ /1NQ boards.

Replace the power block.

Replace the MC unit or harness.