TROUBLESHOOTING
1-95August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Kaaaw sk
ERROR CODE E1090 External modulation data is not input.
(Option)
External modulation data is not received.
Check for abnormality in the external modulation data line and repair as necessary
.
_____________________________________________________________________
ERROR CODE E1091 External modulation data is abnormal.
(Option)
Modulation data is too large.
Check for abnormality in the external modulation data line and repair as necessary
.
_____________________________________________________________________
ERROR CODE E1092 Modulation data is over limit.
(Option)
Modulation data exceeds the set allowable capacity.
Check for abnormality in the external modulation data line and repair as necessary
.
_____________________________________________________________________
ERROR CODE E1093 Incorrect motion instruction to execute modulate motion.
(Option)
A non-modulation instruction is specified.
Specify appropriate modulation instruction.
_____________________________________________________________________
ERROR CODE E1094 Illegal joint number.
Occurs when the DRIVE or other similar command is used and a joint number is speci-
fied that is not part of the robot configuration.
Confirm robot configuration before using the DRIVE or other similar command.