TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-186 August 9, 2005
Kaaaw sk
ERROR CODE P2026 Invalid coordinate value Z.
This error occurs when the work space output signal lower Z value is greater than the
upper value in AUX 0403.
Ensure upper and lower values are set correctly
in AUX 0403
.
_____________________________________________________________________
ERROR CODE P2027 Cannot use signal, already used in I/F panel.
This error occurs when a signal allocated for the I/F panel is used as an OX signal.
Use a signal that is not allocated for the I/F panel.
_____________________________________________________________________
ERROR CODE P2028 Arm ID board is busy.
This error occurs when the 1GV arm ID board is processing data when a flash memory
access command is executed (MNTREC, MNTLOG, etc.).
Execute the flash memory access command after the 1GV arm ID board completes
processing the data.
Defective 1GV arm ID board.
_____________________________________________________________________
ERROR CODE P2029 Axis setting data is incorrect.
The channel number for the external axis is set to a channel number already assigned
to another axis in AUX 2001, External Axis Set.
Ensure the correct channel number is set in AUX 2001 using the values from the
original factory specification sheet.
_____________________________________________________________________
ERROR CODE P2031 Deleted step was destination of Jump, Call instruction.
This error occurs when the destination step for a JUMP or CALL instruction specified by
FN20, FN23, or FN26 is deleted.
Teach a step at the JUMP destination.
Ensure the correct step is designated in FN20, FN23, or FN26.
_____________________________________________________________________