TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-128 August 9, 2005
Kaaaw sk
ERROR CODE E4525 ABMA-PDP) Timeout of sending message. XX
ABMA-PDP module overload, sending message cannot be processed within the allowed
time.
Check the fieldbus cable and connections, repair/replace as necessary
.
Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.
_____________________________________________________________________
ERROR CODE E4526 ABMA-PDP) Timeout of receiving message. XX
ABMA-PDP module overload, receiving message cannot be processed within the al-
lowed time.
Check the fieldbus cable and connections, repair/replace as necessary
.
Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.
_____________________________________________________________________
ERROR CODE E4527 ABMA-PDP) Check configuration data. XX
Incorrect configuration data or bus parameter is downloaded. Download cannot be
completed after error reset.
Use the sub-code XX as a troubleshooting aid, ensure correct configuration data and
bus parameters are used and re-execute download
.
If the number of external I/O signals is changed, cycle controller power OFF and ON.
_____________________________________________________________________
ERROR CODE E4528 PROFIBUS) Slave Diag-error response detected. XX
Incorrect slave diagnosis command parameter is entered. If sub-code XX=A1 (hexa-
decimal notation), the node address used is out of range.
Ensure the correct parameters and node address are used
.
Check the fieldbus cable and connections, repair/replace as necessary
.
_____________________________________________________________________