TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-194 August 9, 2005
Kaaaw sk
ERROR CODE P2069 [FDD/PC_CARD] Device already in use.
Attempting to perform several processes at the same time to/from the floppy disk/PC
card. The next task is commanded while the previously commanded task is in progress.
Allow each task to be completed before initiating another task to/from the floppy disk/
PC card
.
_____________________________________________________________________
ERROR CODE P2070 No more data can be registered.
An attempt is made to set additional signal names or comments beyond the maximum
number allowed in the KLogic program.
Delete unnecessary signal names and comments
.
Initialize all data.
_____________________________________________________________________
ERROR CODE P2071 C/S switch set to disable.
The CYCLE START switch is pressed while the cycle start switch invalid option set ON.
Set the cycle start switch invalid option OFF and re-execute
.
_____________________________________________________________________
ERROR CODE P2072 [LSEQ] Maximum cycles of execution.
While executing the basic operation part of the KLogic program, execution cycle time is
calculated as longer than the cycle time set using the LSQ_CYCMAX (maximum length
of execution cycle) command/instruction. In this case, the program is not executed.
Reduce the number of steps in the program
.
Increase the maximum execution cycle time (if possible).
_____________________________________________________________________
ERROR CODE P2073 [LSEQ] Other program is waiting execution.
During execution of the basic operation part of the KLogic program, an attempt is made
to execute LSQREWRITE. Overwriting program data using the LSQREWRITE com-
mand/instruction is executed after completing the last step of the currently running
program.
Allow the current program execution to complete before executing the LSQREWRITE
command/instruction
.
_____________________________________________________________________