TROUBLESHOOTING
1-51August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Kaaaw sk
ERROR CODE D2011 Parameter download error between user I/F & arm ctrl
boards.
1KA and 1KB boards parameter exchange cannot be downloaded.
Replace the 1KA board.
Replace the 1KB board.
_____________________________________________________________________
ERROR CODE D2012 SOFT ABSORBER error. Turn OFF & ON the control
power.
(Software absorber function)
Main causes include:
1. Abnormality during soft absorber sequence.
2. 1KB board upload/download is requested, but not executed.
Cycle controller power OFF and ON.
Replace the 1KB board.
If the error recurs, contact KRI Customer Service
.
_____________________________________________________________________
ERROR CODE D2013 CHANGE GAIN Error. Turn OFF & ON the control power.
(Change gain function)
Main causes include:
1. Abnormality during change gain sequence.
2. 1KB board upload/download is requested, but not executed.
Cycle the controller power OFF and ON.
_____________________________________________________________________
ERROR CODE D2014 Robot network initialize error.
This error occurs when initialization of the Ethernet board is not successful during
power-up.
Main causes include:
1. 1KA board components do not correspond to Ethernet option.
2. Ethernet MAC address is not set.
3. Defective 1KA board.
Install the appropriate 1KA board and optional 1KN Ethernet board and set the MACaddress.
_____________________________________________________________________