TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-96 August 9, 2005
Kaaaw sk
ERROR CODE E1095 Cannot execute motion instruction in PC program.
A PC program cannot contain instructions that initiate robot motion.
Correct the PC program by removing motion instructions.
_____________________________________________________________________
ERROR CODE E1096 Incorrect auxiliary data settings.
The value selected for auxiliary data (speed, timer, tool etc.) exceeds allowable range.
Correct the value of auxiliary data.
Perform system initialization.
If correct value is entered and this error recurs, contact KRI customer service.
_____________________________________________________________________
ERROR CODE E1097 Missing C1MOVE or C2MOVE instruction.
Program circular motion instructions must have a C1MOVE followed by either a
C1MOVE or C2MOVE and end with a C2MOVE.
Correct program instructions.
_____________________________________________________________________
ERROR CODE E1098 C1MOVE (CIR1) instruction required before C2MOVE.
Program circular motion instructions must have C2MOVE move preceded by a
C1MOVE.
Correct program instructions.
_____________________________________________________________________
ERROR CODE E1099 Unable to create arc path, check positions of the 3 points.
Circular interpolation moves cannot be processed because the points identified are too
close together or are on a straight path.
Correct program instructions.