TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-136 August 9, 2005
Kaaaw sk
ERROR CODE E5024 Pressurization comp. signal has not been detected.
Pressurization completion signal is not received from the weld controller/timer.
Main causes include:
1. Defective weld controller/timer.
2. Defective servo spot weld gun.
3. Defective harness, cable, etc.
Check weld controller/timer, servo spot weld gun, harnesses, and cables and repair/replace as necessary
.
_____________________________________________________________________
ERROR CODE E5025 Gun opening comp. signal has not been detected.
Gun opening completion signal is not received from the servo weld gun.
Main causes include:
1. Defective servo spot weld gun.
2. Defective servo spot weld gun cable, cable connections, tool changer, etc.
Check the servo spot weld gun, servo spot weld gun cable, cable connections, andtool changer contacts and connections and repair/replace as necessary.
_____________________________________________________________________
ERROR CODE E5026 RWC error -xx.
(Spot weld specifications type B)
(-xx: represents the welder number)
The current flow from the specified remote weld controller (RWC) Is abnormal.
Main causes:
20: SCR overheat 21: Memory abnormal
22: Power failure 23: System error
24: Defective electro-valve (gun control valve)
Main causes include:
Insufficient SCR cooling, a memory data error, weld current is not synchronized with gun
clamp conditions, system error, or gun control valves malfunction.
Check welder and weld gun repair/replace as necessary.
Check 1GS board, and communication cables repair/replace as necessary.