TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-180 August 9, 2005
Kaaaw sk
ERROR CODE P1039 Teach pendant is not connected.
The “T” command is executed without the teach pendant connected.
Install teach pendant and re-execute the “T” command.
_____________________________________________________________________
ERROR CODE P1040 Cannot execute this command in I/F panel.
A monitor-command button is set-up on the I/F panel to execute a command that is not
permitted from the I/F panel. When the monitor-command button is pressed this error is
displayed.
Use commands permitted for I/F panel use
.
_____________________________________________________________________
ERROR CODE P1041 Auto monitor command failure.
An error occurrs when a command specified for the auto monitor command function is
executed.
Use the error cause stored in the error log as a troubleshooting aid
.
_____________________________________________________________________
ERROR CODE P1042 NUM program is running.
This error occurs when the NUM program is executed and the NUM program is already
running.
Allow the current program execution to complete before re-executing.
_____________________________________________________________________
ERROR CODE P1043 Cannot execute in REPEAT mode.
Teach mode function is attempted in repeat mode.
���
Ensure teach mode is selected when executing teach mode functions
.
_____________________________________________________________________
ERROR CODE P1044 Cannot execute on because motor power is ON.
An attempt is made to enable motion verification mode while motor power is ON.
Set motor power OFF and re-execute
.
_____________________________________________________________________