TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-110 August 9, 2005
Kaaaw sk
ERROR CODE E1149 Cannot open setting data, so cannot set to shipment state.
When “2: Setting to shipment state” is selected from the initialization screen, a data file
in the setting file (ini_load.cmd) in the 1KA board memory could not be opened.
Ensure the proper setting file
(ini_load.cmd)
is loaded into the 1KA board memory
.
_____________________________________________________________________
ERROR CODE E1150 Cannot read setting data, so cannot set to shipment state.
When “2: Setting to shipment state” is selected from the initialization screen, a data file
in the setting file (ini_load.cmd) in the 1KA board memory could not be decoded.
Ensure the proper setting file
(ini_load.cmd)
is loaded into the 1KA board memory
.
If the proper setting file (ini_load.cmd) is loaded replace the 1KA board.
_____________________________________________________________________
ERROR CODE E1151 Too much data for setting to the shipment state.
When “2: Setting to shipment state” is selected from the initialization screen, more than
10 data files are in the setting file (ini_load.cmd) in the 1KA board memory.
Ensure 10 or less data files are in the setting file
(ini_load.cmd)
loaded into the 1KA
board memory
.
_____________________________________________________________________
ERROR CODE E1152 Name of setting data for shipment state is too long.
When “2: Setting to shipment state” is selected from the initialization screen, the name
of a data file in the setting file (ini_load.cmd) in the 1KA board memory exceeds eight
characters, or the file extension exceeds four characters.
Ensure the file name and extension contains the proper number of characters.
_____________________________________________________________________
ERROR CODE E1153 Power sequence board detects error. (Code=XX)
An error is detected by the 1KP board but the code (Code=XX) could not be interpreted
by the AS software.
Replace the 1KP board
.
If this error recurs after replacing the 1KP board contact KRI customer service.
_____________________________________________________________________