INSTALLATION INFORMATION

ELECTRICAL SUPPLY REQUIREMENTS

WARNING

Electrical Shock Hazard

Electrically ground range.

Failure to do so can result in death, fire, or electrical shock.

GENERAL

2.Wire sizes and connections must conform to the requirements of the National Electri- cal Code, ANSI/NFPA 70—latest edition*, or CSA Standard C22.1, Canadian Elec- trical Code, Part 1—latest edition**, and all local codes and ordinances for the kilowatt rating of the range.

Copies of the standards listed may be obtained from:

*National Fire Protection Association Batterymarch Park

Quincy, Massachusetts 02269

**CSA International

8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575

If codes permit, and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate.

Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure that the range is grounded.

Do not have a fuse in the neutral or ground circuit.

1.When a 4-wire or 3-wire, single-phase, 120/240-volt, 60-Hz, AC-only electrical supply is available, a 50-ampere maxi- mum circuit protection is required, (or, if specified on the model/serial plate, when a 4-wire, or 3-wire, single-phase, 120/ 208-volt, 60 Hz, AC-only electrical supply is available, a 40-ampere maximum circuit protection is required), fused on both sides of the line. A time-delay fuse, or circuit breaker is recommended. The model/se- rial rating plate is located behind the stor- age drawer (see page 1-4).

3.This range can be connected directly to the fused disconnect, or circuit breaker box, through flexible, armored, or nonme- tallic sheathed, copper cable (with ground wire). Locate the junction box to allow two to three feet of slack in the line so that the range can be moved, if servicing is ever necessary. Do not cut the conduit.

A U.L.-listed conduit connector must be provided at each end of the power supply cable, at the range, and at the junction box. Wire sizes, (copper wire only), and connections, must conform with the rating of the range.

2-1