4-20

REMOVING THE DOUBLE LINE BREAK (DLB) RELAYAND THE COOLING FAN MOTOR
1. Unplug range or disconnect power.
2. Open the oven door and remove the racks
from inside the oven.
3. Pull the range away from the wall so that
you can access the rear of the unit.
4. Remove the left side panel (see page 4-19
for the procedure).
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
6. To remove the cooling fan motor:
a) Disconnect the wire connectors from
the cooling fan motor terminals.
5. To remove the double line break (DLB)
relay:
a) Disconnect the wire connectors from
the relay terminals.
b) Remove one of the two relay mounting
screws and loosen the other screw.
Slide the relay out from under the loose
screw and remove it from the housing.
DLB Relay
Red Yel Red
2 Wht
Loosen Screw Remove Screw
b) Remove the storage drawer from the
front of the unit.
Motor
Wires
Cooling Fan Motor