REMOVING THE DOUBLE LINE BREAK (DLB) RELAY

AND THE COOLING FAN MOTOR

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Unplug range or disconnect power.

2.Open the oven door and remove the racks from inside the oven.

3.Pull the range away from the wall so that you can access the rear of the unit.

4.Remove the left side panel (see page 4-19 for the procedure).

5.To remove the double line break (DLB) relay:

a)Disconnect the wire connectors from the relay terminals.

b)Remove one of the two relay mounting screws and loosen the other screw. Slide the relay out from under the loose screw and remove it from the housing.

2 Wht

Red Yel Red

Loosen Screw

Remove Screw

6.To remove the cooling fan motor:

a)Disconnect the wire connectors from the cooling fan motor terminals.

DLB Relay

Motor

Wires

Cooling Fan Motor

b)Remove the storage drawer from the front of the unit.

4-20

Page 46
Image 46
KitchenAid KESC300H Removing the Double Line Break DLB Relay Cooling FAN Motor, To remove the double line break DLB relay