Lennox International Inc DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE DOWNFLOW AIR DISCHARGE

Models: 090V60C 110V60C 090V36C 070V36B DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE DOWNFLOW AIR DISCHARGE

1 64
Download 64 pages 9.7 Kb
Page 4
Image 4
SLP98DFV Gas Furnace

SLP98DFV Gas Furnace

The SLP98DFV category IV gas furnace is equipped with a variable−capacity, variable−speed integrated control. This control ensures compatibility with the Lennox icom- fort Toucht thermostat and Harmony IIIt zone control system, as well as a thermostat which provides humidity control.

The furnace is equipped for installation in natural gas ap- plications only. A changeover kit may be ordered for LP applications.

The SLP98DFV must be installed only as a Direct Vent gas central furnace.

NOTE − In Direct Vent installations, combustion air is taken from outdoors and flue gases are discharged outdoors. See figure 2 for applications including roof termination.

DIRECT VENT INSTALLATION

Shipping and Packing List EXHAUST OUTLET

COMBUSTION

AIR INTAKE

OUTSIDE OF

HOUSE

SLP98DFV

FIGURE 2

Shipping and Packing List

Package 1 of 1 contains

1 − Assembled SLP98DFV unit

1 − Bag assembly containing the following:

3 − Wire nuts

1− Snap bushing

1− Snap plug

1− Wire tie

1− Condensate trap

Check equipment for shipping damage. If you find any damage, immediately contact the last carrier.

The following items may also be ordered separately:

1− Thermostat

1− Natural to LP gas conversion kit

1− High altitude kit

Safety Information

Safety InformationWARNING

Improper installation, adjustment, alteration, service or maintenance can cause property damage, person- al injury or loss of life. Installation and service must be performed by a licensed professional installer (or equivalent), service agency or the gas supplier.

Manual backgroundCAUTION

As with any mechanical equipment, personal injury can result from contact with sharp sheet metal edges. Be careful when you handle this equipment.

Use only the type of gas approved for use with this furnace. Refer to unit nameplate.

Building Codes

In the USA, installation of gas furnaces must conform with lo- cal building codes. In the absence of local codes, units must be installed according to the current National Fuel Gas Code (ANSI-Z223.1/NFPA 54). The National Fuel Gas Code is available from the following address:

American National Standards Institute, Inc.

11 West 42nd Street

New York, NY 10036

Installation Locations and Clearances

In Canada, installation must conform with current National Standard of Canada CSA-B149 Natural Gas and Propane Installation Codes, local plumbing or waste water codes and other applicable local codes.

This furnace is designed for installation clearances to com- bustible material as listed on the unit nameplate and in the table in figure 7. Accessibility and service clearances must take precedence over fire protection clearances.

For installation in a residential garage, the furnace must be installed so that the burner(s) and the ignition source are located no less than 18 inches (457 mm) above the floor. The furnace must be located or protected to avoid physical damage by vehicles. When a furnace is installed in a public garage, hangar, or other building that has a haz- ardous atmosphere, the furnace must be installed accord- ing to recommended good practice requirements and cur- rent National Fuel Gas Code or CSA B149 standard.

NOTE − Furnace must be adjusted to obtain a temperature rise (100% percent capacity) within the range(s) specified on the unit nameplate. Failure to do so may cause erratic limit operation and may also result in premature heat exchanger failure.

This SLP98DFV furnace must be installed so that its elec- trical components are protected from water.

Page 4

Page 4
Image 4
Lennox International Inc DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE DOWNFLOW AIR DISCHARGE, 070V36B SLP98DFV Gas Furnace