Image 59
CALL FOR HEAT SATISFIED

Troubleshooting: Heating Sequence of Operation (Continued)

CALL FOR HEAT SATISFIED

RUN MODE (TWO−STAGE THERMOSTAT)

3A

3B

RUN MODE (SINGLE−STAGE THERMOSTAT)

FIRST OR SECOND−STAGE CALL FOR HEAT

ALL INPUTS MONITORED (LIMIT, PRESSURE,

 

 

ALL INPUTS MONITORED (LIMIT, PRESSURE,

 

 

CALL FOR HEAT/COOL, FLAME LEVEL).

CALL FOR HEAT/COOL, FLAME LEVEL).

 

 

 

2nd Stage Heat

NO

2nd Stage Call for Heat satisfied?

YES

Combustion Air Inducer

switched to 70% rate speed

Adjust Indoor Blower to appropiate speed

 

 

 

 

 

 

1st Stage Heat

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st Stage Call for Heat satisfied?

YES

Gas valve

De−Energized

Combustion Air Inducer OFF after 20−Second Post Purge

Indoor Blower OFF

after OFF Delay

1

OR

4

Wait for Call

 

Wait for Call

Two−Stage

 

Single−Stage

Thermostat

 

Thermostat