BLOWER DATA

SLP98DF090V48C BLOWER PERFORMANCE (less filter)

HEATING BLOWER PERFORMANCE

Heating Adjust CFM Selections

 

 

 

 

Heating Input Range and Blower Volume - CFM

 

 

 

 

 

35%

40%

 

50%

 

60%

 

70%

 

80%

 

90%

 

100%

 

 

 

 

 

 

 

 

 

 

 

 

Increase (+15%) Heat CFM

 

 

 

723

790

 

925

 

1060

 

1195

 

1329

 

1464

 

1599

 

Increase (+7.5%) Heat CFM

 

 

 

690

752

 

878

 

1004

 

1129

 

1255

 

1381

 

1507

 

Default Heat CFM

 

 

 

656

714

 

831

 

948

 

1064

 

1181

 

1297

 

1414

 

Decrease (-7.5% ) Heat CFM

 

 

 

601

654

 

761

 

867

 

974

 

1081

 

1188

 

1295

 

Decrease (-15% ) Heat CFM

 

 

 

545

593

 

690

 

787

 

884

 

981

 

1078

 

1175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING BLOWER PERFORMANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Adjust CFM

 

 

 

 

 

 

 

Blower Speed Selections

 

 

 

 

 

 

 

 

Selections

 

First Stage Cool Speed - cfm

 

 

Second Stage Cool Speed - cfm

 

 

 

 

 

Low

 

 

Medium-

 

Medium

 

High

 

Low

 

Medium-

 

Medium

 

High

 

 

 

 

Low

 

High

 

(Default)

 

 

 

 

 

Low

 

High

(Default)

Increase (+10%) Cool CFM

775

 

940

 

1100

 

 

1255

 

1120

 

 

1340

 

1535

1745

 

Default Cool CFM

690

 

875

 

975

 

 

1135

 

1000

 

 

1220

 

1425

1625

 

Decrease (-10%) Cool CFM

635

 

755

 

915

 

 

1025

 

920

 

 

1100

 

1270

1470

 

SLP98DF090V60C BLOWER PERFORMANCE (less filter)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING BLOWER PERFORMANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Adjust CFM Selections

 

 

 

 

Heating Input Range and Blower Volume - CFM

 

 

 

 

 

35%

40%

 

50%

 

60%

 

70%

 

80%

 

90%

 

100%

 

 

 

 

 

 

 

 

 

 

 

 

Increase (+15%) Heat CFM

 

 

 

653

728

 

877

 

1027

 

1176

 

1326

 

1475

 

1625

 

Increase (+7.5%) Heat CFM

 

 

 

603

673

 

813

 

953

 

1092

 

1232

 

1372

 

1512

 

Default Heat CFM

 

 

 

553

618

 

748

 

878

 

1009

 

1139

 

1269

 

1399

 

Decrease (-7.5% ) Heat CFM

 

 

 

510

570

 

690

 

811

 

931

 

1051

 

1171

 

1292

 

Decrease (-15% ) Heat CFM

 

 

 

467

522

 

632

 

743

 

853

 

963

 

1074

 

1184

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING BLOWER PERFORMANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Adjust CFM

 

 

 

 

 

 

 

 

Blower Speed Selections

 

 

 

 

 

 

 

 

Selections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First Stage Cool Speed - cfm

 

 

Second Stage Cool Speed - cfm

 

 

 

 

 

Low

 

 

Medium-

 

Medium

 

High

 

Low

 

Medium-

 

Medium

 

High

 

 

 

 

Low

 

High

 

(Default)

 

 

 

 

 

Low

 

 

High

(Default)

Increase (+10%) Cool CFM

1110

 

1265

 

1395

 

 

1600

 

1600

 

 

1750

 

1965

2130

 

Default Cool CFM

1000

 

1145

 

1275

 

 

1445

 

1445

 

 

1625

 

1805

1975

 

Decrease (-10%) Cool CFM

885

 

1060

 

1145

 

 

1265

 

1265

 

 

1445

 

1645

1805

 

The effect of static pressure is included in air volumes shown.

The following control configurations are available. See Installation Instructions for details and DIP switch settings.

Heat Modes Available (Heating Blower Performance Table):

Single stage thermostat:

-35%, 70%, 100% input (three-stage) with time delays in-between

Two-stage thermostat:

-Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times

-W1 demand at 70% input, W2 demand at 100% input. No delay between stages

icomfort Touch™ Communicating Thermostat:

-Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times

-35%, 60%, 80%, 100% (four-stage) with time delays in-between

Cool Mode Available (Cooling Blower Performance table):

First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.

Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position minimum 300 cfm.

Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 380 cfm (SLP98DF090V48C) and 450 cfm (SLP98DF090V60C).