Lennox International Inc DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE DOWNFLOW AIR DISCHARGE Page

Models: 090V60C 110V60C 090V36C 070V36B DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE DOWNFLOW AIR DISCHARGE

1 64
Download 64 pages 9.7 Kb
Page 14
Image 14
Manual background

TABLE 7

Maximum Allowable Intake or Exhaust Vent Length in Feet

*Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe size.

Standard Termination at Elevation 0 − 4500’

Number Of

90° Elbows

Used

 

2" Pipe

 

 

2−1/2" Pipe

 

 

3" Pipe

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

Model

 

 

Model

 

 

 

 

 

 

 

 

 

 

070

090

110

070

090

110

070

090

110

 

 

 

 

 

 

 

 

 

1

91

69

14

140

93

43

162

143

118

 

 

 

 

 

 

 

 

 

 

2

86

64

9

135

88

38

157

138

113

 

 

 

 

 

 

 

 

 

 

3

81

59

 

130

83

33

152

133

108

 

 

 

 

 

 

 

 

 

 

4

76

54

 

125

78

28

147

128

103

 

 

 

 

 

 

 

 

 

 

5

71

49

 

120

73

23

142

123

98

 

 

 

 

 

 

 

 

 

 

6

66

44

n/a

115

68

18

137

118

93

 

 

 

 

 

 

 

 

 

7

61

39

110

63

13

132

113

88

 

 

 

 

 

 

 

 

 

 

 

8

56

34

 

105

58

 

127

108

83

 

 

 

 

 

 

 

 

 

 

9

51

29

 

100

53

n/a

122

103

78

 

 

 

 

 

 

 

 

 

 

10

46

24

 

95

48

 

117

98

73

 

 

 

 

 

 

 

 

 

 

Standard Termination Elevation 4501’ − 7500’

Number Of

90° Elbows

Used

 

2" Pipe

 

 

2−1/2" Pipe

 

 

3" Pipe

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

Model

 

 

Model

 

 

 

 

 

 

 

 

 

 

070

090

110

070

090

110

070

090

110

 

 

 

 

 

 

 

 

 

1

66

69

14

115

93

43

137

143

118

 

 

 

 

 

 

 

 

 

 

2

61

64

9

110

88

38

132

138

113

 

 

 

 

 

 

 

 

 

 

3

56

59

 

105

83

33

127

133

108

 

 

 

 

 

 

 

 

 

 

4

51

54

 

100

78

28

122

128

103

 

 

 

 

 

 

 

 

 

 

5

46

49

 

95

73

23

117

123

98

 

 

 

 

 

 

 

 

 

 

6

41

44

n/a

90

68

18

112

118

93

 

 

 

 

 

 

 

 

 

7

36

39

85

63

13

107

113

88

 

 

 

 

 

 

 

 

 

 

 

8

31

34

 

80

58

 

102

108

83

 

 

 

 

 

 

 

 

 

 

9

26

29

 

75

53

n/a

97

103

78

 

 

 

 

 

 

 

 

 

 

10

21

24

 

70

48

 

92

98

73

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Terminatiuon at Elevation 7501’ − 10,000’’

 

 

 

 

 

 

 

 

 

 

 

 

 

Number Of

 

2" Pipe

 

 

2−1/2" Pipe

 

 

3" Pipe

 

 

 

 

 

 

 

 

 

 

90° Elbows

 

Model

 

 

Model

 

 

Model

 

Used

 

 

 

 

 

 

 

 

 

070

090

110

070

090

110

070

090

110

 

 

 

 

 

 

 

 

 

 

 

1

41

44

 

90

68

 

112

118

93

 

 

 

 

 

 

 

 

 

 

2

36

39

 

85

63

 

107

113

88

 

 

 

 

 

 

 

 

 

 

3

31

34

 

80

58

 

102

108

83

 

 

 

 

 

 

 

 

 

 

4

26

29

 

75

53

 

97

103

78

 

 

 

 

 

 

 

 

 

 

5

21

24

 

70

48

 

92

98

73

 

 

 

n/a

 

 

n/a

 

 

 

6

16

19

65

43

87

93

68

 

 

 

 

 

 

 

 

 

 

 

 

7

11

14

 

60

38

 

82

88

63

 

 

 

 

 

 

 

 

 

 

8

 

 

 

55

33

 

77

83

58

 

 

 

 

 

 

 

 

 

 

9

n/a

n/a

 

50

28

 

72

78

53

 

 

 

 

 

 

 

 

 

 

10

 

 

 

45

23

 

67

73

48

 

 

 

 

 

 

 

 

 

 

NOTE − Table 7 continued on next page with concentric terminations.

Page 14

Page 14
Image 14
Lennox International Inc DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE DOWNFLOW AIR DISCHARGE, 070V36B, 090V36C, 110V60C Page