SLP98DF110V60C BLOWER PERFORMANCE (less filter)

BLOWER DATA

SLP98DF110V60C BLOWER PERFORMANCE (less filter)

HEATING BLOWER PERFORMANCE

Heating Adjust CFM Selections

 

 

 

 

Heating Input Range and Blower Volume - CFM

 

 

 

 

 

35%

40%

 

50%

 

60%

 

70%

 

80%

 

90%

 

100%

 

 

 

 

 

 

 

 

 

 

 

 

Increase (+15%) Heat CFM

 

 

 

811

906

 

1096

 

1286

 

1475

 

1665

 

1855

 

2045

 

Increase (+7.5%) Heat CFM

 

 

 

744

835

 

1017

 

1199

 

1380

 

1562

 

1744

 

1926

 

Default Heat CFM

 

 

 

677

764

 

938

 

1112

 

1285

 

1459

 

1633

 

1807

 

Decrease (-7.5% ) Heat CFM

 

 

 

626

707

 

869

 

1031

 

1193

 

1355

 

1517

 

1679

 

Decrease (-15% ) Heat CFM

 

 

 

575

650

 

800

 

950

 

1101

 

1251

 

1401

 

1551

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING BLOWER PERFORMANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Adjust CFM

 

 

 

 

 

 

 

Blower Speed Selections

 

 

 

 

 

 

 

 

Selections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First Stage Cool Speed - cfm

 

 

Second Stage Cool Speed - cfm

 

 

 

 

 

Low

 

 

Medium-

 

Medium

 

High

 

Low

 

Medium-

 

Medium

 

High

 

 

 

 

Low

 

High

 

(Default)

 

 

 

 

 

Low

 

High

(Default)

Increase (+10%) Cool CFM

1090

 

1260

 

1395

 

 

1580

 

1580

 

 

1790

 

1990

2180

 

Default Cool CFM

965

 

1125

 

1285

 

 

1440

 

1440

 

 

1625

 

1845

2000

 

Decrease (-10%) Cool CFM

860

 

1030

 

1125

 

 

1270

 

1270

 

 

1470

 

1655

1845

 

The effect of static pressure is included in air volumes shown.

The following control configurations are available. See Installation Instructions for details and DIP switch settings.

Heat Modes Available (Heating Blower Performance Table):

Single stage thermostat:

-35%, 70%, 100% input (three-stage) with time delays in-between

Two-stage thermostat:

-Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times

-W1 demand at 70% input, W2 demand at 100% input. No delay between stages

icomfort Touch™ Communicating Thermostat:

-Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times

-35%, 60%, 80%, 100% (four-stage) with time delays in-between

Cool Mode Available (Cooling Blower Performance table):

First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.

Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position minimum 300 cfm.

Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 450 cfm.