Front View

FIELD−PROVIDED

1−1/2" (38mm) accelerator

REDUCER MAY BE RE-

provided on 71M80 &

QUIRED TO ADAPT

44W92 kits for

LARGER VENT PIPE

SL98DF070V36B

SIZE TO TERMINATION.

 

OUTSIDE

INTAKE

WALL

AIR

EXHAUST

EXHAUST

AIR

AIR

Front View

EXHAUST VENT

 

SIZE

 

TERMINATION

INTAKE

PIPE PER

TABLE 9.

AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTAKE

 

12" (305mm) Min.

INTAKE

 

CLAMP

 

 

 

 

 

above grade or

AIR

(Not Furnished)

 

 

AIR

 

average snow

 

 

 

 

 

 

 

 

 

 

 

 

accumulation.

 

 

 

 

 

 

 

 

 

 

 

 

GRADE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIRECT VENT CONCENTRIC WALL TERMINATION

 

 

 

 

71M80, 69M29 or 60L46 (US)

 

 

 

 

 

 

 

44W92 or 44W93 (Canada)

 

 

 

FIGURE 24

Top View

1/2" (13mm) Foam Insulation

in Unconditioned Space

FIELD−PROVIDED

REDUCER MAY BE

REQUIRED TO

ADAPT LARGER

VENT PIPE SIZE

TO TERMINATION

EXHAUST VENT

INTAKE AIR

8" (206mm) MIN.

EXHAUST

 

12"

 

(305mm)

VENT

 

5"

5−1/2"

 

(127mm)

(140mm)

INTAKE

 

 

AIR

 

 

 

18" MAX.

Front View

 

(457mm)

EXHAUST VENT

12" (305mm) Min.

above grade or

average snow ac-

Inches (mm)INTAKE cumulation.

AIR

optional intake elbow

Side View

OPTIONAL VENT TERMINATION FOR MULTIPLE UNIT

INSTALLATION OF DIRECT VENT WALL TERMINATION KIT

(22G44, 44J40, 30G28 or 81J20)

 

FIGURE 25

Front View

EXHAUST VENT

 

SIZE

 

TERMINATION

INTAKE

PIPE PER

TABLE 9.

AIR

 

OUTSIDE WALL

DIRECT VENT WALL TERMINATION KIT

(22G44 or 44J40)

FIGURE 27

SLP98 DIRECT VENT APPLICATION

STRAIGHT−CUT OR

USING EXISTING CHIMNEY ANGLE−CUT IN DIRECTION

OF ROOF SLOPE *

 

 

 

 

 

 

 

 

 

3" − 8"

 

EXHAUST VENT

 

 

8" − 12"

 

 

 

 

(76mm−

 

1/2" (13mm)

 

(203mm − 305mm)

 

 

 

 

203mm)

 

 

 

 

 

 

 

WEATHERPROOF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSULATION

 

Minimum 12" (305MM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHOULDER OF FITTINGS

 

 

 

 

 

INTAKE PIPE

 

 

above chimney top

 

 

INSULATION (optional)

 

 

PROVIDE SUPPORT

 

 

 

 

 

 

 

 

 

 

OF PIPE ON TOP PLATE

 

plate or average snow

 

 

 

 

SHEET

 

 

 

 

 

 

 

 

 

 

ALTERNATE

 

 

 

 

 

 

METAL TOP

 

 

 

 

 

accumulation

 

 

 

 

 

 

 

INTAKE PIPE

 

 

 

 

 

PLATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3" − 8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(76mm−

 

 

 

INSULATE

 

 

 

 

 

203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTERIOR

 

 

 

 

TO FORM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORTION OF

 

 

 

 

 

SEAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHIMNEY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*SIZE TERMINATION PIPE PER TABLE 9.

NOTE − Do not discharge exhaust gases directly into any chimney or vent stack. If ver- tical discharge through an existing unused chimney or stack is required, insert piping inside chimney until the pipe open end is above top of chimney and terminate as illus- trated. In any exterior portion of chimney, the exhaust vent must be insulated.

FIGURE 28

Top View

1/2" (13mm) Foam Insulation

 

in Unconditioned Space

 

FIELD−PROVIDED

EXHAUST VENT

REDUCER MAY BE

 

REQUIRED TO

 

ADAPT LARGER

INTAKE AIR

VENT PIPE SIZE

 

TO TERMINATION.

 

 

6 (152mm) MIN.

OUTSIDE WALL

DIRECT VENT WALL TERMINATION KIT

(30G28 or 81J20)

2" EXTENSION FOR 2" PVC PIPE

1" EXTENSION FOR 3" PVC PIPE

FURNACE Manual backgroundManual background INTAKE Manual background

PIPE

4’’

FURNACE

EXHAUST

PIPE

GLUE EXHAUST

END FLUSH INTO

TERMINATION

1−1/2" ACCELERATOR (all −070 and −090 units)

FIGURE 26

FLUSH−MOUNT SIDE WALL TERMINATION KIT 51W11

FIGURE 29