Lenovo TD230 manual Replacing FRUs

Models: TD230

1 186
Download 186 pages 12.12 Kb
Page 103
Image 103

To remove the heat sink and fan assembly, do the following:

1.Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all power cords from electrical outlets and disconnect all cables that are connected to the server.

2.Remove the server cover. See “Removing the server cover” on page 43.

3.Locate the heat sink and fan assembly. See “Locating server components” on page 32.

Note: If a second microprocessor is installed in the server, there will also be a heat sink and fan assembly installed above the second microprocessor.

4.Lay the server on its side for easier operation.

5.Depending on which heat sink and fan assembly you are removing, do one of the following:

If you are removing the heat sink and fan assembly for microprocessor 1, disconnect the heat sink and fan assembly cable from the system fan 2 connector on the system board. See “Locating parts on the system board” on page 33. Then, remove the four screws 1 that secure the heat sink and fan assembly.

Note: Carefully remove the four screws from the system board to avoid any possible damage. The four screws are integrated parts of the heat sink and fan assembly and they cannot be removed from the heat sink and fan assembly.

Figure 63. Screws that secure the heat sink and fan assembly for microprocessor 1

Chapter 5. Replacing FRUs 97