
Basic Operation
|
|
|
|
| Assigning Values | ||||
Once you have assigned a Destination, press Load /✱ to get to the Values |
|
|
|
| |||||
display. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| |||
Patch 0 | Values |
| The current Dst value is displayed here. When you press | ||||||
✱000: | Off |
| Load /✱ again, the asterisk will move to indicate that this value | ||||||
|
|
|
|
|
| ||||
|
|
|
| is available to be changed by turning ADJUST. |
|
| |||
|
|
|
|
| |||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| |
Src values are shown here. The asterisk (✱) indicates | Patch 0 | Values | |||||||
that this field is available for control with the ADJUST | 000: ✱ | Off | |||||||
knob (and that additional parameters are available by | |||||||||
|
|
|
| ||||||
pressing Load /✱). |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
This display allows you to assign Destination values to specific Source values. These assignments are made in pairs, each with a value for the Source and a value for the Destination. For example, the default is two pairs mapped as follows:
minimum Src value (0) = minimum Dst value
maximum Src value (127) = maximum Dst value
This establishes a linear relationship between the parameter and the controller. Inverse control is accomplished easily by reversing these settings. As many as eight pairs of Destination/Source values, or pivot points, can be assigned here, providing an exciting new level of dynamic control.
Jump
When creating patches, there are situations in which you will want to leave the Patch row to adjust parameters. To make this convenient, a Jump command is available. Jumping is dependent on the current Patch display, and is activated simply by pressing Edit while a certain display is active. This will jump you out of the Patch row and to the location where you can make the necessary adjustments. Pressing Edit again will jump you back to the Patch Row. (Note that using any front panel controls other than those required to adjust the parameter to which you have jumped, will disable the jump. This is not catastrophic, but it will require you to return by using Up and Down and SELECT.) The following Jumps are available:
From the Patch row Src display:
•With ADJUST selected as the Source, press Edit to jump to the Controls row, where you can specify range limits for the ADJUST knob. Press Edit again to return to the Patch row.
•With any modulation parameter selected as a Source, press Edit to jump to the Modulation row position of the Source. For example, if the Patch source LFO is displayed, press Edit to jump to Modulation row position 0 (LFO) where you can edit any LFO parameter value. Press Edit again to return to the Patch row.