Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-41

F-41

TROUBLESHOOTING & REPAIR

METER CIRCUIT ACCURACY TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid elec- trical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshoot- ing assistance before you proceed. Call 216-383-2531 or 1-800-833-9353 (WELD).

DESCRIPTION

This test will help determine if the LN-9 GMA meter circuit is functioning properly.

MATERIALS NEEDED

Phillips head screwdriver

Digital volt/ohmmeter (multimeter) with at least 3-1/2 digits and ± 0.5% accuracy Slot head screwdriver

3/8" Nut driver

This procedure takes approximately 17 minutes to perform.

LN-9 GMA Wire Feeder

Page 105
Image 105
Lincoln Electric SVM138-A service manual Meter Circuit Accuracy Test, Description