F-21

 

 

 

 

F-21

TROUBLESHOOTING & REPAIR

 

 

 

 

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

detailed in the beginning of this manual.

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

STARTING PROBLEMS

 

 

 

 

 

The output voltage is too low to

1. Check the welding cables for

1. Check the

voltage

control

start the weld.

loose or faulty connections.

potentiometer

(R3)

and

the

 

2. Put the Lincoln power source in

associated leads.

See

the

 

Wiring Diagram.

 

 

 

 

the "Machine Control" mode.

 

 

 

 

 

 

 

 

 

 

Jumper the "BYPASS" pins on

2. The voltage PC board may be

 

the LN-9 GMA voltage PC

faulty. Replace.

 

 

 

 

board. Adjust the weld voltage

 

 

 

 

 

 

from the power source for the

 

 

 

 

 

 

process being used. If the cor-

 

 

 

 

 

 

rect voltage cannot be set, the

 

 

 

 

 

 

power source may be faulty.

 

 

 

 

 

 

3. Check for correct control cable

 

 

 

 

 

 

connections to the power supply.

 

 

 

 

 

 

4. The control cable may be faulty.

 

 

 

 

 

 

Check or replace.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

LN-9 GMA Wire Feeder

Page 85
Image 85
Lincoln Electric SVM138-A service manual Starting Problems