F-7

 

 

F-7

TROUBLESHOOTING & REPAIR

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

The wire feeds when the gun trig-

 

1. Make sure the interlock switch

1.

The 1CR relay, located on the

ger is activated, but there is no arc

 

is in a "Wire Hot" position.

 

power PC board, may be faulty.

voltage.

 

2. Check the welding cables for

 

Check or replace.

 

 

 

 

 

 

loose or faulty connections.

2. If a burnback kit is installed,

 

 

3. Put a jumper wire from #2 to #4

 

remove and install the jumper

 

 

 

plug. If the problem is solved,

 

 

on the power source terminal

 

 

 

 

the burnback kit is faulty.

 

 

strip. (Machines with 14 pin

 

 

 

 

 

 

 

amphenols: pin C to pin D.) If

3.

Check the #2 and #4 leads in

 

 

the arc voltage is not present at

 

the LN-9 GMA wiring harness

 

 

the output terminals, the power

 

for loose or faulty connections.

 

 

source is faulty. If the arc volt-

 

See the Wiring Diagram.

 

 

age IS present, the problem is

 

 

 

 

in the wire feeder or control

 

 

 

 

cable.

 

 

 

 

4. Check the continuity of leads #2

 

 

 

 

and #4 through the control

 

 

 

 

cable. Replace if "open."

 

 

 

 

 

 

 