TROUBLESHOOTING & REPAIR

T2 TRANSFORMER TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid elec- trical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshoot- ing assistance before you proceed. Call 216-383-2531 or 1-800-833-9353 (WELD).

DESCRIPTION

This test will aid the technician in determining if the T2 transformer is functioning.

MATERIALS NEEDED

115VAC power supply Phillips head screwdriver Volt/ohmmeter (multimeter)

This procedure takes approximately 20 minutes to perform.

LN-9 GMA Wire Feeder

Page 91
Image 91
Lincoln Electric SVM138-A service manual T2 Transformer Test, Description