Test Digital Meter Accuracy. (For LN-9 GMA models above code 7980 with separable digital meter and meter boards only).

1.Use a test meter with at least 3-1/2 digits and

± 0.5% accuracy.

2.Connect the + probe to TP4 and the - probe to lead #510C.

NOTE: The coating will have to be removed from the test points.

3.With the meter in SET volts, adjust the voltage control until the test meter matches the set- tings in the table below.

If the LN-9 GMA digital meter does not match the readings, the LN-9 GMA digital meter may be faulty. Replace the digital meter.

LN-9 GMA SET

TEST VOLTMETER

VOLTS READING

READING

 

 

15.0 V

.150 ± .004 VDC

30.0 V

.300 ± .004 VDC

60.0 V

.600 ± .006 VDC

 

 

Test Meter PC Board Voltage Accuracy.

(All Models)

1.Use a test meter with at least 3-1/2 digits and

± 0.5% accuracy.

2.Connect the + probe to leads #517 and the - probe to lead #510C.

NOTE: The coating will have to be removed from the test points.

3.With the meter in SET volts, adjust the voltage control until the LN-9 GMA meter matches the settings in the table below.

If the test meter does not match the readings, the meter PC board may be faulty. Replace the meter PC board.

LN-9 GMA SET

TEST VOLTMETER

VOLTS READING

READING

 

 

15.0 V

1.50 ± .05 VDC

30.0 V

3.00 ± .05 VDC

60.0 V

6.00 ± .07 VDC

 

 

Test Meter PC Board Wire Feed Speed

Accuracy. (For LN-9 GMA, LN-9F GMA Models

Only)

1.Use a test meter with at least 3-1/2 digits and

± 0.5% accuracy.

2.Connect the + probe to lead #519 and the - probe to lead #510C.

NOTE: The coating will have to be removed from the test points.

3.With the meter in SET IN/MIN, adjust the speed control until the LN-9 GMA meter matches the settings in the table below. If the test meter does not match the readings, the meter PC board may be faulty. Replace the meter PC board.

LN-9 GMA SET

TEST VOLTMETER

VOLTS READING

READING

 

 

082 IPM

0.50 ± .05 VDC

489 IPM

3.00 ± .05 VDC

978 IPM

6.00 ± .07 VDC

 

 