F-23

 

 

F-23

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

STARTING PROBLEMS

 

 

 

The arc voltage appears to rise too

1.

Adjust the "start" trimmer on the

1. The voltage PC board may be

 

slowly or stubs or blasts at the start

 

voltage PC board. It should be

faulty. Replace.

 

of a weld. Once started the weld-

 

slightly higher than the weld

 

 

 

ing is good.

 

voltage. See Starting Charac-

 

 

 

NOTE: Pulse Power 500 operation

 

teristics in the Operation section

 

 

 

 

of this manual.

 

 

 

with a filter kit may exhibit these

 

 

 

 

 

 

 

 

 

symptoms.

3.

Put the Lincoln power source in

 

 

 

 

 

the "Machine Control" mode.

 

 

 

 

 

Jumper the "BYPASS" pins on

 

 

 

 

 

the LN-9 GMA voltage PC

 

 

 

 

 

board. Adjust the weld voltage

 

 

 

 

 

from the power source for the

 

 

 

 

 

process being used. If the cor-

 

 

 

 

 

rect voltage cannot be set, the

 

 

 

 

 

power source may be faulty.

 

 

 

 

4. Check for correct control cable

 

 

 

 

 

connections to the power supply.

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

LN-9 GMA Wire Feeder

Page 87
Image 87
Lincoln Electric SVM138-A service manual Starting Problems