Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-42

F-42

TROUBLESHOOTING & REPAIR

METER CIRCUIT ACCURACY TEST (continued)

FIGURE F.10 – METER PC BOARD LOCATIONS AND COVER

MOUNTING SCREWS

TEST PROCEDURE

1.Remove input power to the LN-9 GMA wire feeder.

2.Lift the right side cover assembly and remove the two screws holding the meter cover to the right side assembly. Carefully remove the meter cover. See Figure F.10.

3.Locate and gain access to the meter PC board. See Figure F.10.

4.Apply input power to the wire feeder.

WARNING

ELECTRIC SHOCK can kill.

With power applied, there are high voltages inside the wire feeder. Do not reach into the wire feeder or touch any internal part of the wire feeder while power is applied.

LN-9 GMA Wire Feeder

Page 106
Image 106
Lincoln Electric SVM138-A service manual Meter Circuit Accuracy Test, Figure F.10 Meter PC Board Locations and Cover