TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

detailed in the beginning of this manual.

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

METER FUNCTION PROBLEMS

 

 

 

The arc is unstable or oscillating.

1. Check the welding cables for

 

1. The LN-9 GMA voltage PC

 

loose or faulty connections.

 

board may be faulty. Replace.

 

2. Make sure the electrode and

 

 

 

 

gas (if used) are correct for the

 

 

 

 

process being used.

 

 

 

 

3. Put the Lincoln power source in

 

 

 

 

the “Machine Control” mode.

 

 

 

 

Jumper the “BYPASS” pins on

 

 

 

 

the LN-9 GMA voltage PC

 

 

 

 

board. Adjust the weld voltage

 

 

 

 

from the power source for the

 

 

 

 

process being used. If the prob-

 

 

 

 

lem is NOT resolved, the power

 

 

 

 

source may be faulty.

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.