F-45

F-45

TROUBLESHOOTING & REPAIR

METER CIRCUIT ACCURACY TEST (continued)

Test Meter PC Board Wire Feed Speed Accuracy.

(Metric Models Only)

1. Use a test meter with at least 3-1/2 digits and

± 0.5% accuracy.

2.Connect the + probe to lead called for in the table below and the - probe to lead #510C.

NOTE: The coating will have to be removed from the test points.

3.With the meter in SET M/MIN, adjust the speed control until the LN-9 GMA meter matches the set- tings in the table below. If the test meter does not match the readings, the meter PC board may be faulty. Replace the meter PC board.

METRIC MODEL

METRIC RANGE

SET M/MIN READING

TEST VOLTMETER

 

 

 

READING

LN-9 GMA or LN-9F GMA

LO

8.28

LEAD #560

 

 

 

2.00 ± .05VDC

 

HI

24.8

LEAD #561

 

 

 

6.00 ± .07VDC

 

 

 

 

LN-9 GMA Wire Feeder