D-4

D-4

MAINTENANCE

Return to Section TOC

Return to Section TOC

GUN CABLE CONNECTOR REQUIRE- MENTS TO PERMIT PROPER CONNEC- TION TO LINCOLN LN-9 GMA AND LN-9F GMA WIRE FEEDER

The following Figures D.2 and D.3 should serve as a guide to determine if a particular gun or switch can be connected to the LN-9 GMA and LN-9F GMA.

FIGURE D.2 – LN-9 GMA CONNECTORS

 

 

“A” Diameter Hole

 

 

to be Concentric to

Wire Size

.749/.747 (19.0/18.9)

in. (mm)

Diameter Within .008 (.20) F.I.M.

 

 

 

0.68-5/64

(1.7-2.0)

.125 [1/8” (3.2 mm) Drill]

 

 

1/16-0.062 (1.6)

.078 [5/64” (2.0 mm) Drill]

 

 

 

.045 & .052

(1.1 & 1.3)

.062 [1/16” (1.6 mm) Drill]

 

 

 

.023-.035

(0.6-0.9)

.055 [(1.4 mm) #54 Drill]

 

 

 

All dimensions in inches and (millimeters).

FIGURE D.2 – SWITCH REQUIREMENTS

1/2 Amp AC 24 Volts — Inductive

1/2 Amp DC 24 Volts — Inductive

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

LN-9 CONNECTOR FOR 1/16-5/64” (1.6-2.0 MM) WIRE)

LN-9 CABLE CONNECTOR FOR .023-.052” (0.6-1.3 mm)

WIRE (FOR ALL OTHER DIMENSIONS, SEE DIAGRAM

ABOVE).

NOTE: Connector part with .7459/.747 (19.0/18.9) diameter should be made from brass if it is to be part of the welding current carrying circuit.

LN-9 GMA Wire Feeder

Page 58
Image 58
Lincoln Electric SVM138-A service manual Figure D.2 LN-9 GMA Connectors