F-19

 

INSTALLATION

 

 

 

 

F-19

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING GUIDE

 

 

 

 

 

 

Observe Safety Guidelines

 

 

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

METER FUNCTION PROBLEMS

 

 

 

 

 

 

 

 

The SET and actual speed meter

1.

Contact your

local

Lincoln

 

1.

Perform

the

Hall

Effect

 

readings match within a few IPM,

 

Authorized

Field

Service

 

 

Alignment Procedure.

 

 

 

but both are in error.

 

Facility.

 

 

 

2.

Perform

the

Meter

Circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accuracy Test.

 

 

 

 

 

 

 

 

 

3.

The control PC board may be

 

 

 

 

 

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

SET speed and actual speed meter

1.

Contact your

local

Lincoln

 

1.

Check the Volts-Speed meter

 

readings do NOT match within a

 

Authorized

Field

Service

 

 

selector switch and the associ-

 

few IPM. One or both readings

 

Facility.

 

 

 

 

ated wiring.

See the

Wiring

 

may be erratic.

 

 

 

 

 

 

Diagram.

 

 

 

 

 

 

 

 

 

 

 

2.

Check the SET-ACTUAL switch

 

 

 

 

 

 

 

 

and the associated wiring. See

 

 

 

 

 

 

 

 

the Wiring Diagram.

 

 

 

 

 

 

 

 

 

3.

Perform

the

Hall

Effect

 

 

 

 

 

 

 

 

Alignment Procedure.

 

 

 

 

 

 

 

 

 

4.

Perform

the

Meter

Circuit

 

 

 

 

 

 

 

 

Accuracy Test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LN-9 GMA Wire Feeder

Page 83
Image 83
Lincoln Electric SVM138-A service manual Hall Effect