F-4

 

 

F-4

 

TROUBLESHOOTING & REPAIR

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

FUNCTION PROBLEMS

 

No wire feed when gun trigger is

1. Make sure 115VAC is being

1. Check for loose or faulty lead

activated.

The digital meter does

applied to the LN-9 GMA at the

connections between the input

NOT light.

The drive rolls do not

input connector. Pin "C" is lead

connector, the T1 transformer,

turn.

 

#31 and pin "D" is lead #32.

and the power PC board.

 

 

2. Check the 3 amp circuit breaker.

2. The T1 transformer may be

 

 

Reset if tripped.

faulty. Perform the T1 Trans-

 

 

3. The F101 4/10 amp slow blow

former Test.

 

 

 

 

 

fuse, located on the power PC

 

 

 

board, may be blown.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.