WIRE DRIVE MOTOR TEST (continued)

Return to

Return to Section TOC

Return to Section TOC

Return to

Return to Master TOC

Return to Master TOC

WARNING

ELECTRIC SHOCK can kill.

With power applied, there are high voltages inside the wire feeder. Do not reach into the wire feeder or touch any internal part of the wire feeder while power is applied.

6.Apply 115 VAC power.

7.With the gun trigger activated or the gun ter- minals jumpered together (see the Wiring Diagram), check the motor armature volts at leads #541(+) and #539(-). Normal is 5 to 95VDC depending on the wire feed speed setting. As the armature voltage is increased the wire feed speed should increase.

8.If the above voltages are present and the motor does not operate, the motor, motor brushes or gear box may be faulty.

If the armature voltage is missing or not cor- rect, the power board or 1CR relay may be faulty.

If the motor is running at high speed and the armature voltage is high and uncontrollable, proceed with the Hall Effect Module Test.