F-55

F-55

TROUBLESHOOTING & REPAIR

DIGITAL METER AND METER PC BOARD REMOVAL AND

REPLACEMENT (continued)

METER PC BOARD REMOVAL

2. Locate and remove the two screws on the top

PROCEDURE

left and right side of the meter panel assem-

 

bly. See Figure F.13.

1.Remove input power to the LN-9 GMA Wire Feeder.

FIGURE F.13 – METER PANEL ASSEMBLY SCREWS

MOUNTING SCREWS

METER

3. Lift the right side cover assembly.4. Carefully remove the meter enclosure panel. Note the limited lead length. See Figure F.14.

FIGURE F.14 – METER REMOVAL (WITH SHORT LEADS)

LN-9 GMA Wire Feeder

Page 119
Image 119
Lincoln Electric SVM138-A service manual Digital Meter and Meter PC Board Removal, Replacement, Procedure