Return to Section TOC

Return to Master TOC

F-49

F-49

TROUBLESHOOTING & REPAIR

OUT OF VOLTAGE RANGE SHUT DOWN TEST (continued)

FIGURE F.12 – VOLTAGE PC BOARD WITH JUMPERS

Return to Section TOC

Return to Master TOC

BYPASS PINS

1/8 AMP FUSE

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Remove input power to the LN-9 GMA wire feeder.

2.Using the phillips head screwdriver, remove the screws from the left side cover assembly.

3.Lift the left side cover assembly.

4.Locate the voltage PC board. Jumper together the "BYPASS" pins on the LN-9 GMA voltage PC board. See Figure F.12. (On older voltage boards these pins may be labeled "B".) This should disable the shut down circuit.

5.Connect to a Lincoln Electric CV power source per connection diagram. See the Installation section of this manual.

6.Start welding and observe the ACTUAL volt- age reading on the LN-9 GMA digital meter. The actual voltage must match the SET volt- age within ± 0.5V. If it does NOT, the LN-9 GMA is designed to shut down.

7.If the LN-9 GMA continues to shut down with the "BYPASS" pins jumpered together, the voltage PC board may be faulty.

Return to Section TOC

Return to Master TOC

WARNING

ELECTRIC SHOCK can kill.

With power applied, there are high voltages inside the wire feeder. Do not reach into the wire feeder or touch any internal part of the wire feeder while power is applied.

LN-9 GMA Wire Feeder

Page 113
Image 113
Lincoln Electric SVM138-A service manual OUT of Voltage Range Shut Down Test, Figure F.12 Voltage PC Board with Jumpers