TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

detailed in the beginning of this manual.

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

FUNCTION PROBLEMS

 

 

The LN-9 GMA shuts down while

1. Make sure the power source

1. Perform the Out of Voltage

welding. Upon retriggering the

and wire feeder polarity switch-

Range Shutdown Test.

gun, the unit will weld again for a

es are set correctly for the

2. The control cable may be faulty.

period of time.

process being used.

Check or replace.

 

 

 

2. Make certain the voltage control

3. The voltage PC board may be

 

switch on the Lincoln CV power

 

faulty. Replace.

 

source is set in the "Remote"

 

 

 

 

position.

 

 

 

3. Make sure the #21 lead in the

 

 

 

control cable has continuity to

 

 

 

the work piece.

 

 

 

4. Check the 1/8 amp fuse on the

 

 

 

LN-9 GMA voltage PC board.

 

 

 

Replace if faulty.

 

 

 

5. Be sure the welding power

 

 

 

source is compatible with the

 

 

 

LN-9 GMA.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.