TROUBLESHOOTING & REPAIR

VOLTMETER ACCURACY TEST (continued)

FIGURE F.9 – VOLTMETER CONNECTION POINT

BRASS

CONDUCTOR

BLOCK

Return

Return

TEST PROCEDURE

Perform the following checks with the LN-9 GMA wire feeder connected to a Lincoln CV welding power source according to the proper connection diagram. (See the Installation section of this manual.)

See Figure F.9 for this test.

1.Lift the right side cover assembly.

2.Connect the test meter (see Materials Needed) between the brass conductor block on the wire feeder and the work piece.