EXTERNAL CONSOLE SPEAKER CONNECTION (OPTIONAL)

An external console speaker sounds system tones and alerts occupants with a loud siren during alarm.

With the VB-2 module installed, the Central Station can talk to the occupants through the external console speaker.

Use an 8-ohm, 10 watt minimum rated speaker. Do not use a horn/siren with a built-in siren driver.

Up to two 8-ohm speakers can be used with each Console.Up to 150 feet of 22 AWG wire can be used with each speaker. Mount the external speaker. Route the speaker wires from the external speaker to the Console. Open the Console top cover and locate the main terminal block. Route the speaker wires up through the wiring access hole. Remove the wire jumper from the EXT. SPKR & (-) terminals. Connect the speaker wires to the EXT. SPKR & (-) terminals.

NOTE: If connecting two external speakers,

EXTERNAL

CONSOLE

LINEAR SECURITY CONSOLE MODEL DVS-2400

 

 

MAIN TERMINAL BLOCK

 

 

 

AC

 

 

 

AC

 

ANNUNCIATOR

EXT. SPKR(S)

EXT. SPKR

 

VOLUME

8 OHM/10 WATT

(-)

MAIN

CONTROL

2 SPKRS MAX.

H/A -

 

NOTE: REMOVE

TERMINAL

 

H/A +

BLOCK

OPTIONAL

JUMPER FOR

RELAY N.O.

 

VOICE MODULE

EXT. SPEAKERS

RELAY DRY

 

MODEL: VB-2 OR VB-3

 

 

EXTERNAL

CONSOLE

SPEAKER

8 OHM, 10 WATT

MINIMUM

REMOVE

connect the second speaker in parallel, to the

same EXT. SPKR & (-) terminals as the first

speaker.

The system tone volume can be adjusted with the annunciator volume control.EXTERNAL ALARM SIREN CONNECTION (OPTIONAL)

An external siren alerts occupants and neighbors with a loud siren during alarm.

Use a 12 volt, 1 amp maximum rated weather-resistant horn speaker with a built-in siren driver. Do not use a plain speaker.

JUMPER

CONNECT SPEAKER LEADS TO EXT. SPKR & (-) TERMINALS

EXTERNAL

ALARM

NOTE: Connection of an electromechanical bell or motor bell is not recommended because of the radio interference generated when the bell is running.

Mount the external siren. Route the wires from the external siren to the Console. Open the Console top cover and locate the main terminal strip. Route the siren wires up through the wiring access hole. Connect the siren wires to the RELAY N.O. & (-) terminals.

NOTE: By removing the Console’s auxiliary fuse, the relay contacts will become isolated. Use the RELAY N.O. & RELAY DRY terminals to switch an externally powered load.

LINEAR SECURITY CONSOLE MODEL DVS-2400

 

 

MAIN TERMINAL BLOCK

 

 

 

AC

 

 

 

AC

 

 

EXTERNAL SIREN

EXT. SPKR

 

 

(-)

 

 

12 VDC 1 AMP

MAIN

 

H/A -

 

MAXIMUM

TERMINAL

 

 

H/A +

BLOCK

OPTIONAL

 

RELAY N.O.

 

VOICE MODULE

 

RELAY DRY

 

MODEL: VB-2 OR VB-3

 

 

EXTERNAL

ALARM RELAY 12 VDC 1 AMP MAXIMUM

CONNECT SIREN LEADS TO (-) & RELAY N.O. TERMINALS