AWAY MODE

Use this mode when no one will be staying home.

Each burglary sensor can trigger the siren once per arming period.

Away Mode causes an instant alarm when any perimeter sensor is triggered.

Away Mode causes a delayed alarm when any exit/entry sensor is triggered.

Away Mode causes an instant alarm when any interior sensors (motion detectors, etc.) are triggered. The interior sensors will be delayed if a perimeter delayed sensor is triggered first.

Alarm siren stops automatically after five minutes and the system will remain armed.

Arm to Away Mode by entering a user code, and pressing [AWAY].

The user can “Quick Arm” to Away Mode from Home, Chime or Off Mode by holding down the [AWAY] key for two seconds. (Quick arming can be disabled; see the “Advanced Programming” section of this manual.)

EXIT DELAY (For Leaving the Premises)

When the system is armed to the Away Mode, the Console will sound a “Gong” and three “Beeps”.

During the 60 second Exit Delay, the Console will sound “beeps” (double beeps last 10 seconds) and the AWAY light will blink.

The Exit Delay gives the user 60 seconds to

leave the premises through an exit/entry door

without triggering an alarm.

MANUAL BYPASSING OF SENSORS

Manual bypassing of sensors in the Away Mode allows arming of the system with open doors and windows, while still having perimeter protection with other closed doors and windows.

The Console will resist arming with open door or window sensors.

Four high-low beeps to warn the user that something is open and the system will remain in the previous mode.

Lit sensor status indicators show which sensors are open.

To manually bypass the open sensors, arm the system again within 5 seconds.

A “gong” and three “beeps” will sound, the AWAY indicator will light, and the open sensors will be bypassed.

WARNING: Bypassed sensors cannot cause an alarm.

AWAY MODE

START HERE

Re-entering during the Exit Delay will extend the

Exit Delay another 60 seconds (one time only).

When the Exit Delay is over, the Console will sound one “gong” to warn the user that the system is fully armed.

NOTE: The Exit Delay time can be changed; see the “Advanced Programming” section of this manual.

ENTRY DELAY (For Entering the Premises)

The Entry Delay gives the user 30 seconds to

enter the premises through an exit/entry door

without triggering an alarm.

If a exit/entry sensor is triggered, starting the

AWAY

(OPTIONAL)

YOUR

USER

CODE

1 GONG

& 3 BEEPS

Entry Delay, the interior sensors will also

become delayed (this allows motion in the

premises during the Entry Delay).

During the 30 second Entry Delay, the Console will sound “beeps”.

When the Entry Delay is over, the Console will go into full alarm and sound the siren if it is not disarmed to the Off or Chime Mode.

If an alarm has occurred while the user was gone, multiple beeps will sound after disarming and the sensor light for the sensor(s) that caused the alarm will flash (switch to Off Mode again or re-arm the Console to stop the flashing alarm memory light).

NOTE: The Entry Delay time can be changed; see the “Advanced Programming” section of this manual.

DONE

QUICK ARM

START HERE

HOLD

AWAY DOWN

1 GONG

& 3 BEEPS DONE

19