◆The Console can be programmed with five restricted user codes and one page alert user code.
◆The restricted user codes operate the system as usual, but cannot access Setup Mode.
◆The restricted user codes can access a special Code Mode that can be used to change or remove any of the five restricted user codes, the page alert user code, or the duress code.
◆The page alert user code dials the supervisory number (programmed for a pager) when it is used to ARM OR DISARM the system.
◆A restricted user code is a good one to give to children or any user that should be restricted from programming the Console.
✍NOTE: For maximum security, a
✍WARNING: NEVER PROGRAM ANY RESTRICTED OR PAGE ALERT USER CODE THE SAME AS THE MASTER USER CODE!
PROGRAMMING STEPS #93 TO 98
PROGRAM
STORE PROGRAM
STEP # 93 RESTRICTED USER CODE #1
STEP # 94 RESTRICTED USER CODE #2
STEP # 95 RESTRICTED USER CODE #3
STEP # 96 RESTRICTED USER CODE #4
STEP # 97 RESTRICTED USER CODE #5
STEP # 98 PAGE ALERT USER CODE
◆Any restricted, duress or page alert user code can be removed from the Console.
◆Because access to programming would be impossible without a master user code, it cannot be removed using these steps.
9 WXY KEYPAD CODE PROGRAMMING STEPS #92 TO 98
TEST REMOVE
✍NOTE: The master user code can be removed using the Console master reset, although all other system programming with be reset to factory values and all sensors programmed will be erased.
CONSOLE MASTER RESET | START IN TEST |
| ||
◆ Master resetting the Console will set all of the |
| |||
|
|
| ||
programming options back to the factory values. |
|
|
| |
The master user code will be reset to 1234. |
| MASTER |
| |
✍CAUTION: Master resetting the Console will erase |
| USER |
| |
| CODE |
| ||
the user codes and remove all programmed sensors. |
|
| ||
|
|
| ||
All Console and communicator programming values |
|
|
| |
will be reset to the factory defaults. |
| 1 GONG & |
| |
Start with the system in Test Mode (Setup | TEST |
| ||
5 BEEPS |
| |||
|
|
| ||
Mode cannot be reached from any other mode). |
|
|
| |
From the Test Mode, enter the master user code | 9 WXY | STEP #999 |
| |
|
| |||
then press [TEST]. |
|
| ||
9 WXY | FOR | USE THESE EXACT | ||
❇ A “Gong” and five “Beeps” will sound, signaling | MASTER | |||
| KEYSTROKES | |||
that the system is in Setup Mode. |
| RESET | ||
| TO PERFORM A | |||
9 WXY |
| |||
Enter programming Step #999. |
| MASTER RESET | ||
|
| |||
|
|
| ||
Press [TEST]. | TEST | PRESS |
| |
Enter the numbers 999 again. | TEST |
| ||
|
| |||
|
|
| ||
Press [TEST] again. | 9 WXY |
|
| |
❇ A “Bing” will sound to indicate the beginning of |
| ENTER 999 |
| |
the reset process. This process will take up to 10 | 9 WXY | TO OK THE |
| |
seconds while the memory is being reset. |
| MASTER |
| |
| RESET |
| ||
◆ The system will revert to the first time | 9 WXY |
|
| |
|
|
| ||
condition and the new master user code will be |
| PRESS TEST, |
| |
1234. Go to the “Basic Console Programming” | TEST | 1 BING SOUNDS, |
| |
WAIT ABOUT 10 |
| |||
section of this manual to begin |
|
| ||
| SECONDS |
| ||
the system. | DONE |
|
31