ADDITIONAL USER CODES

The Console can be programmed with five restricted user codes and one page alert user code.

The restricted user codes operate the system as usual, but cannot access Setup Mode.

The restricted user codes can access a special Code Mode that can be used to change or remove any of the five restricted user codes, the page alert user code, or the duress code.

The page alert user code dials the supervisory number (programmed for a pager) when it is used to ARM OR DISARM the system.

A restricted user code is a good one to give to children or any user that should be restricted from programming the Console.

NOTE: For maximum security, a 3-5 digit code is recommended.

WARNING: NEVER PROGRAM ANY RESTRICTED OR PAGE ALERT USER CODE THE SAME AS THE MASTER USER CODE!

PROGRAMMING STEPS #93 TO 98

PROGRAM

1-5 DIGIT CODE

(3-5 DIGITS RECOMMENDED)

STORE PROGRAM

STEP # 93 RESTRICTED USER CODE #1

STEP # 94 RESTRICTED USER CODE #2

STEP # 95 RESTRICTED USER CODE #3

STEP # 96 RESTRICTED USER CODE #4

STEP # 97 RESTRICTED USER CODE #5

STEP # 98 PAGE ALERT USER CODE

Log the restricted user codes in the boxes.
REMOVING USER CODES

Any restricted, duress or page alert user code can be removed from the Console.

Because access to programming would be impossible without a master user code, it cannot be removed using these steps.

9 WXY KEYPAD CODE PROGRAMMING STEPS #92 TO 98

TEST REMOVE

The master user code can be changed using programming Step #99.

NOTE: The master user code can be removed using the Console master reset, although all other system programming with be reset to factory values and all sensors programmed will be erased.

CONSOLE MASTER RESET

START IN TEST

 

Master resetting the Console will set all of the

 

 

 

 

programming options back to the factory values.

 

 

 

The master user code will be reset to 1234.

 

MASTER

 

CAUTION: Master resetting the Console will erase

 

USER

 

 

CODE

 

the user codes and remove all programmed sensors.

 

 

 

 

 

All Console and communicator programming values

 

 

 

will be reset to the factory defaults.

 

1 GONG &

 

Start with the system in Test Mode (Setup

TEST

 

5 BEEPS

 

 

 

 

Mode cannot be reached from any other mode).

 

 

 

From the Test Mode, enter the master user code

9 WXY

STEP #999

 

 

 

then press [TEST].

 

 

9 WXY

FOR

USE THESE EXACT

A “Gong” and five “Beeps” will sound, signaling

MASTER

 

KEYSTROKES

that the system is in Setup Mode.

 

RESET

 

TO PERFORM A

9 WXY

 

Enter programming Step #999.

 

MASTER RESET

 

 

 

 

 

Press [TEST].

TEST

PRESS

 

Enter the numbers 999 again.

TEST

 

 

 

 

 

 

Press [TEST] again.

9 WXY

 

 

A “Bing” will sound to indicate the beginning of

 

ENTER 999

 

the reset process. This process will take up to 10

9 WXY

TO OK THE

 

seconds while the memory is being reset.

 

MASTER

 

 

RESET

 

The system will revert to the first time power-up

9 WXY

 

 

 

 

 

condition and the new master user code will be

 

PRESS TEST,

 

1234. Go to the “Basic Console Programming”

TEST

1 BING SOUNDS,

 

WAIT ABOUT 10

 

section of this manual to begin re-programming

 

 

 

SECONDS

 

the system.

DONE

 