13. COMMUNICATOR PROGRAMMING

SETUP MODE

To perform any of the communicator
programming steps, the Console must be in the
Setup Mode.
Each programming function is performed with
similar keystrokes. After the Console is in Setup
Mode, enter the programming step number,
press the [HOME] key (HOME = program), enter
the new value, and press the [AWAY] key
(AWAY = store). Follow the figures next to the
programming step.

SETUP MODE

START IN TEST

Start with the Console in Test Mode (Setup Mode cannot be reached from any other mode).

From Test Mode, enter the master user code then press [TEST].

NOTE: Only the master user code can be used to put the Console into the Setup Mode. The restricted user codes cannot access Setup Mode.

A “gong” and five “beeps” will sound, signaling that the Console is in Setup Mode.

Hold the [OFF] key for three seconds when you want to exit Setup Mode.

NOTE: If the Console is left unattended in Setup Mode, it will automatically switch back to Off Mode after three minutes.

TEST

MASTER USER CODE

1 GONG &

5 BEEPS

GENERAL COMMUNICATOR OPTIONS

STEP #

PROGRAMMING

 

POSSIBLE

FACTORY

INSTALLATION

FUNCTION

 

VALUES

VALUE

VALUE

 

 

 

 

 

 

 

 

76

2-WAY AUDIO

0

= NONE; 1 = LISTEN; 2 = 2-WAY MANUAL; 3 = 2-WAY FULL DUPLEX

0

 

78

VOICE RESPONSE FROM CONSOLE SPEAKER

0

= VOICE RESPONSE DISABLED

0

 

(AND REMOTE SPEAKER IF USED)

1

= VOICE RESPONSE ENABLED

 

 

 

 

100

REMOTE PROGRAMMING LOCKOUT

0

= UNLOCK; 1 = LOCK

0

 

101

CALL LIMITER

0

= OFF; 1 = FIVE CALLS PER ARMING PERIOD

0

 

103

DIALING DELAY

0

= NO DELAY; 1 = 30 SECOND DELAY

0

 

104

DIALING METHOD

0

= TONE; 1 = PULSE

0

 

107

COMMUNICATOR ENABLE

0

= COMMUNICATOR OFF, 1 = COMMUNICATOR ON

0

 

General Communicator Programming Table