CALL LIMITER

The factory setting for the call limiter is OFF. This allows the communicator to report burglary alarms, once for each sensor, as many times as they are triggered.

Optionally, the Console can be programmed to only allow five burglary reports total per arming period.

NOTE: Sensors programmed to 24-hour functions (Emergency, Panic, Fire) always send a Central Station Report and always sound the local siren regardless of the Call Limiter setting.

1

0PROGRAMMING STEP #101

1

HOME PROGRAM

0 FOR OFF (UNLIMITED)

1 FOR ON (5 VIOLATIONS)

AWAY STORE PROGRAM

DIALING DELAY

The factory setting will cause the communicator to dial the Central Station instantly when an alarm or supervisory event occurs.

Alternately, the communicator can be programmed to wait 30 seconds before dialing. This gives the user time to disarm the system and prevent communications in the case of a subscriber generated false alarm.

PROGRAMMING STEP #103

PROGRAM

0 FOR NO DELAY

1 FOR 30 SECOND DELAY

STORE PROGRAM

DIALING METHOD

The factory setting causes the communicator to dial using DTMF (dual-tone multi-frequency) tone dialing.

Alternately, the communicator can be programmed to use pulse (rotary) dialing. Use this option if the telephone line in the installation does not support tone dialing.

1

0PROGRAMMING STEP #104

4GHI

HOME PROGRAM

0 FOR TONE DIALING

1 FOR PULSE DAILING

AWAY STORE PROGRAM

34