10AUXILIARY FUSE

★Type 2AG, 1-amp fuse.

★Protects the external relay output when used with wet contacts (12 VDC switched out).

★Fuse will blow when load exceeds 1 amp.

✍WARNING: For continued protection against the risk of fire, replace only with the same type and rating of fuse.

11MAIN TERMINAL BLOCK

★Terminals for connection to the plug-in AC transformer.

★Terminals for connection to an external speaker.

★Automation Output to connect to an automation controller.

★External relay output for “wet” contacts (switched 12 volts) or “dry” contacts (normally open 1 amp @ 24 volts maximum).

12BATTERY FUSE

★Type 2AG, 3-amp fuse for the backup battery.

★If the POWER light is flashing and the optional backup battery is installed and charged, check this fuse.

✍WARNING: For continued protection against the risk of fire, replace only with the same type and rating of fuse.

13TELEPHONE TERMINAL BLOCK

★Provides telephone connections for the digital communicator.

★Provides telephone connection for voice prompted telephone remote control (optional VB-2 digital voice synthesis module required).

★Provides seized ring and tip connections for local telephone instruments. Communicator will disconnect local telephones while on-line.

14INTERNAL SPEAKER CONNECTOR

★Connects the internal speaker to the Console circuit board.

★2-pin connector, non-polarized.

15ANTENNA TERMINALS

★Antenna and ground terminals for receiving signals from the system’s sensors.

★Pre-wired to the Console’s internal wire dipole antenna.

★Alternately connects to the Model LA-P local whip and remote antenna kit.

16OPTIONAL BACKUP BATTERY

★Space for 12-volt, 1.2 amp/hour backup battery. (Highly recommended.)

★Backup battery is automatically charged and monitored by the Console.

★Backup battery can power the Console for up to 6 hours.

18

19

17WIRING ACCESS HOLE

★Provides access to recessed wiring trough in base of Console.

★Route cables for power, telephone, external speaker, etc. through this hole.

★Loop for zip-tie strain relief provided next to hole.

18WALL-MOUNT SLOTS

★Used when mounting Console recessed in the wall.

★Two mounting brackets (supplied) slide through slots and are retained by screws, clamping the unit to the wall.

19RADIO TEST POINTS

★Used to monitor the Console’s radio receiver during troubleshooting.

★Provides connection for an audio amplifier to listen to the receiver’s output.

★Helpful to determine sources of radio interference.

20MICROPHONE (WITH MODEL VB-2 INSTALLED ONLY)

★High sensitivity microphone.

★Detects room audio when communicator is reporting to the Central Station in 2-way audio mode (Model VB-2 digital voice synthesis module must be installed).

21ANNUNCIATOR VOLUME CONTROL

★Varies the volume of the advisory tones that come from the speaker.

★Does not affect internal or external sirens (they are always full volume).

22DIGITAL VOICE SYNTHESIS MODULE (OPTIONAL)

★Two voice synthesis modules are available, the Model VB-2 and VB-3.

★Both modules allow remote command of the Console using a standard pushbutton telephone, on or off site.

★Both modules provide optional human voice prompts from the Console’s speaker.

★The Model VB-2 gives the Console’s digital communicator listen-only, manual 2-way and full duplex 2-way audio capability with the Central Station.