COMMUNICATOR REPORTING CODES

◆The two-digit communicator reporting code for each event has a factory set value. These values may be customized to fit the specific installation and the reporting requirements of the Central Station monitoring the system.

◆If Point ID reporting is enabled (the factory
default setting), each sensor can report a unique

HOME = PROGRAM

TEST = REMOVE

alarm and trouble code.

 

 

◆ If Point ID is disabled, the “general” reporting

AWAY

= STORE
codes for each event type will be used.

 

 

◆Each programming function is performed with similar keystrokes. After the Console is in Setup Mode, enter the programming step number, press the [HOME] key (HOME = program), enter the new value, and press the [AWAY] key (AWAY = store).

◆Making a value 0 causes event to not communicate to central station.

✍NOTE: The reporting codes are fixed for opening and closing. A unique code is reserved for the master and the five restricted user codes. See the Opening & Closing Reporting Codes Table.

GENERAL REPORTING CODES

◆Program Steps #201 - 206 for the communicator reporting codes when Point ID is disabled.

◆Refer to the Console & General Reporting Codes table to view/edit the reporting codes for each of the five events. The factory settings are listed, along with a blank area to write in the new installation values.

◆Any value from 0-99 can be programmed for each event (0 = no report).

✍NOTE: Be careful not to duplicate codes unless the Central Station requires specific codes for certain types of events.

2ABC

PROGRAMMING STEPS

0#201 TO #206

HOME PROGRAM

0 - 99 FOR GENERAL ALARM REPORTING CODE

AWAY STORE PROGRAM

SYSTEM REPORTING CODES◆Program Steps #261 - 266 for the Console reporting codes.

◆Refer to the System Reporting Codes table to view/edit the reporting codes for the keypad [FIRE] and [EMERGENCY] buttons and for each of the four Control Panel conditions. The factory settings are listed, along with a blank area to write in the new installation values.

2 ABC

PROGRAMMING STEPS

6 MNO

#261 TO #266

 

HOME PROGRAM

0 - 99 FOR SYSTEM REPORTING CODE

AWAY STORE PROGRAM

GENERAL REPORTING CODES

STEP #

PROGRAMMING

POSSIBLE

FACTORY

INSTALLATION

FUNCTION

VALUES

VALUE

VALUE

 

 

 

 

 

 

201

GENERAL FIRE REPORT CODE

0 - 99

1

 

202

GENERAL EMERGENCY REPORT CODE

0 - 99

2

 

203

GENERAL SILENT PANIC REPORT CODE

0 - 99

3

 

204

GENERAL BURGLARY REPORT CODE

0 - 99

4

 

206

GENERAL TROUBLE REPORT CODE

0 - 99

6

 

General Reporting Codes Table