PROGRAMMING DIFFERENT SENSOR TYPES

Follow the instructions on the previous page to select a sensor number to program the sensor into.

NOTE: A sensor can be programmed into more than one location. Be sure to choose an unused sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function.

To add DXS-10 wireless keypads, press and hold the keypad’s [] key until programmed into the Console.

IMPORTANT NOTE: The DXS-31 & DXS-32 door/window sensors are pre-set at the factory for delayed burglary response. If the sensor is going to be used on a non-entry portal (window, sliding glass door, etc.) a jumper can be changed in the sensor to select instant response. The jumper should be changed before learning the sensor so the Console will program the sensor to the proper function. See the “Basic Sensor Installation” section of this manual for details on changing the jumper.

For DXS-31 and DXS-32 door/window sensors, move the magnet away from the side of the sensor.

For DXS-81, DXS-91, DXS-54, & DXS-72 accessory sensors, simply send a test transmission (refer to the sensor’s instructions for details on sending a test transmission). For DXT-61, DXT-21, DXS-21 & DXT-41 single-button remotes, simply press the unit’s button. The unit will function as an arm/disarm remote.

NOTE: After the Console “learns” the transmitter, single-button remotes can easily be re-programmed as “panic buttons” or home automation controllers. Refer to Page 24 in the “Customizing the System” section of this manual.

For DXT-23 & DXT-42 multi-button remotes: Learn the transmitter by pressing the left button. The remote will arm the Console with the left button and disarm with the right. Labels are provided with the DXT-42 for identifying the buttons.

NOTE: After the Console “learns” the transmitter, multi-button remotes can easily be re-programmed to have the left button arm/disarm the Console and the right button activate/deactivate the Home Automation Output. Refer to Page 24 in the “Customizing the System” section of this manual.

A single “bing” tone will sound and the sensor status indicator will stay lit when the sensor is learned by the Console.

A double “buzz” tone will sound if there is already another sensor programmed to that sensor number.

Exit Setup Mode by holding the [OFF] button for two seconds. Reminder: The Console will automatically exit the Setup Mode and return to Off Mode after 3 minutes of keypad inactivity.

NOTE: To remove sensors from the Console’s memory, see Page 22 in the “Customizing the System” section of this manual.

SEND SIGNAL WITH LEFT BUTTON

LEFT = ARM

RIGHT = DISARM

BOTH = EMERGENCY

13