TEST MODE

Even though this is a self-monitoring supervised system, the National Burglar and Fire Alarm Association recommends that all security systems should be tested manually on a regular basis.

The Console must be in Off Mode before going to Test Mode.

Switch the Console into Test Mode by entering a user code and pressing [TEST].

TEST MODE

START IN OFF

When the system is switched to the Test Mode, the Console will sound a “Gong” and four “Beeps”.

Holding down the [TEST] button in Test Mode will light all of the Console’s indicators.

The sensor status lights will flash for each sensor programmed into the Console.

Go to each sensor and press its test button or open and close the protected opening.

To test the wireless keypad, press the [(A)] key.

The Console will make a “bing” sound as each

sensor is tested, followed by 1-3 beeps indicating

signal strength with 3 beeps being the strongest

TEST

(OPTIONAL)

YOUR

USER

CODE

1 GONG

& 4 BEEPS

signal.

As each sensor is tested, the sensor status light

for the sensor will stop flashing and return to

showing the current status of the sensor.

Continue testing until there are no flashing status lights.

NOTE: If the Console is left unattended in Test Mode, it will automatically switch back to Off Mode after 3 minutes.

DONE

When directly connecting (without a telephone line) to the DVS-2400 with the RA-2400 remote access software (Version 1.3 or later), press the [EMERGENCY] key while in Test Mode to cause the Console to connect to the modem.

SENSOR OPERATION IN EACH CONSOLE MODE

SENSOR FUNCTION

OFF MODE

CHIME MODE

 

HOME MODE

AWAY MODE

 

 

 

 

 

AUTOMATION

 

ACTIVATES AND DEACTIVATES THE AUTOMATION OUTPUT

 

EMERGENCY

 

ARMED 24-HOURS - TRIGGERS EMERGENCY ALARM

 

PANIC

 

ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM

 

FIRE

 

ARMED 24-HOURS - TRIGGERS FIRE ALARM

 

PERIMETER

DEACTIVATED

CHIME

 

INSTANT BURGLARY ALARM

EXIT/ENTRY

DEACTIVATED

CHIME

 

DELAYED BURGLARY ALARM

 

 

 

 

 

FOLLOWER

INTERIOR

DEACTIVATED

DEACTIVATED

 

DEACTIVATED

(INSTANT BURGLARY ALARM

 

UNLESS ACTIVATED DURING

 

 

 

 

 

 

 

 

 

 

ENTRY DELAY)

CHIME

 

CHIME

 

 

2-BUTTON ARM/DISARM (LEFT)

LEFT BUTTON SWITCHES CONSOLE TO AWAY MODE †

 

 

 

2-BUTTON AUTOMATION (RIGHT)

 

LEFT BUTTON SWITCHES TO OFF MODE ‡

IF ALARM HAS OCCURED, SWITCHES CONSOLE TO OFF MODE ‡

 

EMERGENCY (BOTH)

 

 

 

 

 

 

 

 

2-BUTTON ARM (LEFT)

LEFT BUTTON SWITCHES CONSOLE TO AWAY MODE †

 

 

 

2-BUTTON DISARM (RIGHT)

 

RIGHT BUTTON SWITCHES TO OFF MODE ‡

IF ALARM HAS OCCURED, SWITCHES CONSOLE TO OFF MODE ‡

 

EMERGENCY (BOTH)

 

 

 

 

 

 

 

 

ENVIRONMENTAL

 

ARMED 24-HOURS - TRIGGERS ANNUNCIATION ONLY

 

INTERIOR HOME

DEACTIVATED

DEACTIVATED

 

INSTANT BURGLARY ALARM

† CAN BE HOME MODE USING PROGRAMMING STEP 50

Sensor Function Table

 

 

‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51

 

 

 

 

20