COMMUNICATOR REPORTING OPTIONS
REPORTING FORMAT

The factory setting causes the communicator to report using the 4 by 2 format. This format allows four-digit account numbers from 0000 to 9999 and provides two-digit alarm codes.

Alternately ADEMCO CONTACT ID can be chosen as a reporting format. This format allows 4-digit account numbers from 0000 to 9999 and provides verbose report descriptions with Ademco Contact ID compatible Central Stations.

1

0PROGRAMMING STEP #105

5JKL

PROGRAM

HOME

0 FOR 4 BY 2

1 FOR ADEMCO CONTACT ID

AWAY

STORE PROGRAM

CALL ROUTING

The factory setting for the communicator is to route all calls to the primary telephone number. If communication is unsuccessful after five attempts to the primary number, the secondary number will be dialed for an additional five attempts. If the secondary number cannot be reached, the communicator will “sleep” for five minutes before starting the call process over again. A total of five sleep cycles (50 call attempts) can occur before the communicator stops calling.

Alternately, the communicator can be programmed to report supervisory events (low batteries, radio trouble, etc.) to the supervisory telephone number instead of the primary or secondary telephone numbers.

CAUTION: If the page alert user code feature is going to be used, the supervisory number is reserved for the pager number. DO NOT SET THE CALL ROUTING OPTION TO “1”.

8TUV

6MNO

HOME

AWAY

PROGRAMMING STEP #86

PROGRAM

0 FOR ALL TO PRIMARY/SECONDARY 1 FOR ALARMS ONLY TO

PRIMARY/SECONDARY

STORE PROGRAM

To disable supervisory reports, set call routing option to “1” and remove the supervisory telephone number or in 4 by 2 set the report to 0.

NOTE: Do not program the primary and secondary telephone numbers the same. See the FCC Telephone Rules and Regulations on the rear cover of this manual.

COMMUNICATOR REPORTING OPTIONS

STEP #

PROGRAMMING

 

 

POSSIBLE

FACTORY

INSTALLATION

FUNCTION

 

 

VALUES

VALUE

VALUE

 

 

 

 

 

 

 

 

 

 

 

0

= ALL CALLS TO PRIMARY OR SECONDARY NUMBER

 

 

86

CALL ROUTING

1

= ALL ALARM CALLS TO PRIMARY OR SECONDARY NUMBER AND

0

 

 

 

ALL OTHERS TO SUPERVISORY NUMBER

 

 

88

ACCOUNT NUMBER

4 DIGITS

 

EMPTY

 

89

PRIMARY PHONE NUMBER

UP TO 20 DIGITS

EMPTY

 

90

SECONDARY PHONE NUMBER

UP TO 20 DIGITS

EMPTY

 

91

SUPERVISORY/ PAGER PHONE NUMBER

UP TO 20 DIGITS

EMPTY

 

 

 

PRESSING THE (A) KEY INSERTS A 1-SECOND DELAY

 

 

 

FOR ALL PHONE NUMBERS ⇒⇒⇒⇒

THE [FIRE] KEY INSERTS A 5-SECOND DELAY

 

 

 

THE [CHIME] KEY INSERTS A “*

 

 

 

 

THE (A) KEY INSERTS A “#” IF IT IS THE LAST DIGIT OF THE PHONE

 

 

 

 

NUMBER

 

 

 

105

REPORTING FORMAT

0

= 4 BY 2; 1 = ADEMCO

0

 

108

REPORT CONSOLE TROUBLE

0

= NO; 1

= YES

0

 

110

REPORT FORCE ARMING

0

= NO; 1

= YES

0

 

111

OPEN/CLOSE

0

= NO; 1

= YES; 2 = MASTER PAC ONLY

0

 

113

POINT ID REPORTING FOR 4 BY 2 FORMAT

0

= NO; 1

= YES

1

 