◆Connect the Console to the telephone line if the system is monitored, requires
◆Telephone ring & tip terminals are for connection to the incoming telephone line.
◆Seized telephone ring & tip are for connection to local telephone sets. When the communicator activates, all the local telephone sets will be disconnected to prevent an






Connect the incoming telephone line wires to the Console’s telephone terminal block TIP and RING terminals.
◆Connect the local telephone set wires to the Console’s telephone terminal block SEIZED TIP and SEIZED RING terminals.
◆When directly connecting (without a telephone line) to the
TELEPHONE
TERMINAL LINEAR SECURITY CONSOLE MODEL
BLOCK
|
|
| TELEPHONE TERMINAL BLOCK | ||
|
| SEIZED RING |
| TIP | |
|
| SEIZED TIP |
| RING | |
|
| TO LOCAL | R T R1 T1 | TO PHONE | |
OPTIONAL |
| PHONES | LINE | ||
|
|
|
|
| |
VOICE MODULE |
|
|
|
|
|
MODEL: |
|
|
|
| |
SEIZED | SEIZED | LINE | LINE |
|
|
TIP (T1) | RING (R1) | TIP (T) | RING (R) |
|
TELEPHONE
TERMINAL
BLOCK
BROWN
RED
GRAY GREEN
|
|
|
|
|
|
|
|
| BLUE, ORANGE | ||
MODULAR |
|
|
|
|
|
|
|
|
| ||
PHONE CORD |
|
|
|
|
|
|
|
|
| BLACK, AND |
|
|
|
|
|
|
|
|
|
| YELLOW NOT |
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| USED |
|
| R1 |
|
| R | T |
|
| T1 | SHORTING BAR | ||
USOC |
|
|
|
|
|
|
|
|
| SHORT REMOVED | |
(OR |
|
|
|
|
|
|
|
|
| ON PLUG |
|
JACK |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | INSERTION |
|
| R |
|
|
|
|
|
|
|
| T1 | TO LOCAL |
TO TELEPHONE | T |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| TELEPHONE | ||
|
|
|
|
|
|
|
|
| R1 | ||
NETWORK |
|
|
|
|
|
|
|
|
|
| SETS |
CONNECT TELEPHONE LINE
TO THE TELEPHONE
TERMINAL BLOCK
◆The Console provides a Automation Output to control lights, devices and appliances.
◆Automation Output can connect to most popular home automation devices and other simple electronic devices (see Figure).


◆ There are many programmable options for the |
Automation Output. |
◆ The Automation Output can be programmed for |
LINEAR SECURITY CONSOLE MODEL
MAIN
TERMINAL
BLOCKOPTIONAL VOICE MODULE
MODEL:
MINUS H/A TERMINAL WILL SWITCH TO GROUND WHEN AUTOMATION OUTPUT IS ACTIVATED
MAIN TERMINAL BLOCK
| AC |
LIGHT EMITTING | AC |
EXT. SPKR | |
DIODE (L.E.D.) | |
| H/A - |
| H/A + |
| RELAY N.O. |
| RELAY DRY |
POSITIVE H/A TERMINAL PROVIDES +12 VOLTS DC AND IS CURRENT LIMITED AT 30 MILLIAMPS MAXIMUM
a variety of useful functions, such as: flashing |
during alarm, flashing after an alarm, on while |
armed, or, on during exit/entry delays. |
◆ See the “Advanced Programming” section of this |
manual for details on changing the function of |
the Automation Output. |
10
EXAMPLE AUTOMATION OUTPUT
| LINEAR |
|
| |
BURGLAR ALARM |
|
| ||
RELAY MODULE |
|
| ||
INTERFACE | YOUR |
| ||
|
|
| ||
| (CAN CONTROL |
| LOAD | LIGHT |
| HOUSE LIGHTS |
|
| |
|
|
| EMITTING | |
| THROUGH |
|
| |
|
|
| DIODE | |
| SYSTEM) |
|
| |
|
|
| (L.E.D.) | |
|
|
|
| |
|
|
| POWER |
|
|
|
| SOURCE |
|
H/A + H/A - |
| H/A + H/A - |
| H/A + H/A - |