Figure 3.5 Replacing an AC Module (Left Module shown partially removed)

Installation

Figure 3.5 Replacing an AC Module (Left Module shown partially removed)

Note

To remove the AC Module, you only need to loosen the one captive screw on the Module. You do not need to remove the chassis from your rack, or remove the cover of the chassis for any reason. The photo above shows the cover removed for clarity only.

Insert the replacement Power Module in its place (it will require a slight amount of force to insert), and tighten the screw. After the screw is tightened, reconnect the IEC cordset to the Module, and then you can turn the switch on the Module to the On (I) position. When proper power is restored, the front panel display indicating a module has failed will clear after a few moments.